DataSheet8.cn


PDF ( 数据手册 , 数据表 ) L10-HS1E-N2

零件编号 L10-HS1E-N2
描述 Switch Handle Assemblies
制造商 Sprecher Schuh
LOGO Sprecher Schuh LOGO 


1 Page

No Preview Available !

L10-HS1E-N2 数据手册, 描述, 功能
Disconnect Switches
Series L10
UL/CSA Fused Disconnect Switches
Switch (typical)
Amp
Rating
(A)
30
60
Maximum Horsepower
1 Ø (60Hz)
Three Phase (60Hz)
DC
120V 240V 200V 240V 460V 600V 125V 250V Catalog Number
UL Class J and CSA HRCI-J Fuses
o b s o l e t e2 3 7.5 7.5 15 20 3 5 L10-NJ030P3
3 10 15 15 30 50 5 10 L10-NJ060P3
100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NJ100P3
200 ~ 10 ~ 60 125 150 ~ 40 L10-NJ200P3
400 ~
30 2
~ 100 125 250 300 ~
CSA HRCII-C Fuses
3 7.5 7.5 15 20 ~
50 L10-NJ400P3
~ L10-NA200P3
60 3 10 15 15 30 50 ~ ~ L10-NA300P3
100 ~ 15 25 30 60 75 ~ ~ L10-NH100P3
200 ~ 30 50 60 125 150 ~ ~ L10-NH200P3
400 ~ 50 100 125 250 300 ~ ~ L10-NH400P3
UL/CSA Non-Fused Disconnect Switches
Switch (typical)
Amp
Rating
(A)
1 Ø (60Hz)
120V 240V
Maximum Horsepower
Three Phase (60Hz)
200V 240V 460V 600V
DC
125V 250V
Catalog Number
30 2 3 7.5 7.5 15 20 3 5 L10-NN030P3
60 3 10 15 15 30 50 5 10 L10-NN060P3
L 100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NN100P3
200 ~ 10 ~ 60 125 150 ~ 40 L10-NN200P3
400 ~ ~ 100 125 250 300 ~ 50 L10-NN400P3
Note: L10 Fusible and Non-fusible Disconnect Switches with
dimension codes D, E & F require lugs. Sprecher + Schuh lugs
available on page L49.
Price
362 A1
471 B1
744 C1
1641 D1
3136 F1
362 A1
471 B1
744 D1
1641 E1
3136 F1
Price
305 A2
414 B2
744 C1
1641 D1
3136 F1
Ordering Instructions
• Specify Disconnect Switch catalog number (page L46)
• Specify desired switch handle catalog number (page L47)
• Specify desired operating shaft catalog number (page L48)
• Specify desired accessories (page L49)
Time delay fuses may be required to utilize the disconnect switch at its maximum
horsepower rating.
Only UL listed Class J and CSA Certified HRCI-J fuses are suitable for use with
these disconnect switches.
Non-fused disconnect switches must use separately installed UL Listed Class J, CC
or T fuses or CSA Certified HRCI-J fuses.
L46 Discount Schedule B-7
http://www.Datasheet4U.com







L10-HS1E-N2 pdf, 数据表
Technical Information
Series L10 Disconnect Switches
Non-Fused Disconnect Switches for CSA and UL Class Applications
Electrical Ratings
Standards and Approvals (see page L32)
Maximum Fuse Cartridge Size
Maximum Voltage
AC
DC
Ampere Rating
Max. Short Circuit Prospective
Fault Current
Fuse Operating Characteristics
Maximum HP
3AC
200V, 60Hz
230V, 60Hz
460V, 60Hz
575V, 60Hz
L10-
NN030P3
L10-
NN060P3
L10-
NN100P3
[A] 30
60
100
[V] 600 600 600
[V] 250 250 250
[A] 30
60 100
[kA] 100
Non-time
Time Delay
100
Non-time
Time Delay
100
Non-time
Time Delay
[HP] 7.5 3 15 7.5 25 15
[HP] 7.5 3 15 7.5 30 15
[HP] 15 5 30 15 60 25
[HP] 20 7.5 50 15 75 30
1AC 115V, 60Hz
230V, 60Hz
[HP] 2
[HP] 3
0.5 3 1.5 7.5 –
1.5 10 3 15 7.5
DC 125V DC
250V DC
Mechanical Ratings
Degree of Protection (per IEC 947)
Switch only
Switch with Terminal Shields
and Fuse Cover(s)
Mechanical Endurance
Handle Mechanism
Operating Torque (max.)
Terminal Capacity
Power terminals
Auxiliary contact terminals
Max. number of auxiliary contact blocks
Approximate Weight
Minimum Enclosure Size
Height
Width
Depth
[HP]
[HP]
[operations]
[Nm]
[Lb.-In.]
[mm2]
[AWG]
[mm2]
[AWG]
[kg.]
[lbs.]
[mm]
[in.]
[mm]
[in.]
[mm]
[in.]
32
55
IP20
IP20
10,000
4
35
2.5…6
#14…#8
2.5…4
#14…#12
4
0.81
1.78
248
9 3/4
171
6 3/4
111
4 3/8
55––
10 10 20 20
IP20
IP20
10,000
4
35
2.5…25
#14…#4
2.5…4
#14…#12
4
1.14
2.52
248
9 3/4
197
7 3/4
111
4 3/8
IP00
IP20
10,000
17.5
155
2.5…35
#14…#2
2.5…4
#14…#12
4
4.31
9.50
330
13
301
11 27/32
162
6 3/8
L10-
NN200P3
L10-
NN400P3
200
400
600 600
250 250
200 400
100
Non-time
Time Delay
100
Non-time
Time Delay
50 25 100 50
60 25 125 50
125 50 250 100
150 60 300 125
––––
25 15 50 25
––––
40 40 50 50
IP00
IP20
8,000
20.3
180
16…120
#6…250MCM
2.5…4
#14…#12
4
6.56
14.47
560
22
344
13 17/32
178
7
IP00
IP20
8,000
31.4
275
Two 50…150
Two 1/0…350MCM
2.5…4
#14…#12
4
14.97
33.00
762
30
424
16 45/64
243
9 9/16
L
Non-fused disconnects must use separately installed CSA Certified HRCI-J, HRCI-T
or HRCI-MISC (also UL Listed as Class CC) fuses; or UL Listed Class J, CC or T
fuses.
When using CSA HRCI-J, HRCI-MISC (also UL Listed as Class CC) or HRCI-T fuses,
and UL Class J, CC or T fuses.
Based on Sprecher + Schuh tests in accordance with the requirements as defined
in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL98.
Line and load terminal shields supplied as standard.
See L10 Power Wire Installation on page L58.1 for power terminal torque ratings.
Discount Schedule B-7
L53














页数 14 页
下载[ L10-HS1E-N2.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
L10-HS1E-N2Switch Handle AssembliesSprecher Schuh
Sprecher Schuh

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight