DataSheet8.cn


PDF ( 数据手册 , 数据表 ) OC200

零件编号 OC200
描述 Orthoceph Service Program Manual
制造商 Instrumentarium
LOGO Instrumentarium LOGO 


1 Page

No Preview Available !

OC200 数据手册, 描述, 功能
Orthopantomograph® OP200 & OP200 D
Orthoceph® OC200 & OC200 D
Service Program Manual
5140241-100 rev 3
Free Datasheet http://www.datasheet4u.net/







OC200 pdf, 数据表
1 Introduction
1.3 Service program quick reference
Sr
70
Log
Sr
71
PAy
Sr
72
LCA
Sr
74
IOC
Sr
76
PUP
Sr
77
Prh
Sr
78
thA
Sr
79
SUP
Sr
80
CrL
Sr
81
bPL
Sr
82
COL
Sr
87
LAL
SERVICE PROGRAM
REFERENCE TABLE
ERROR LOG PROGRAM
Display failure counters.
SET TRIAL PERIOD LIMIT
Set the length of the trial period (lease time).
LATERAL CASSETTE ADJUSTMENT
(Film units only)
Adjust the symmetry of TMJ image areas.
INPUT / OUTPUT SIGNAL CHECK
Display the states of the CPU's input/output signals.
WARMING UP SEQUENCE
Warm up the X-ray tube after installation or when the
unit has not been used in a while.
PREHEAT ADJUSTMENT
Perform an automatic preheat adjustment.
DOSE CALIBRATION CONSTANT SELECTION
Set the dose calibration constant according to the
tubehead's dose rate.
LINE VOLTAGE DISPLAY
Display the line voltage.
INDIVIDUAL MOTOR MOVEMENT TESTS
Test drive individual motors to ensure proper
operation.
BITEPLATE TEST PROGRAM
Display the currently attached biteplate and the
corresponding input voltages (only with VT enabled).
COLLIMATOR INFORMATION PROGRAM
Display collimator configuration and I/O signal states.
LINEAR ADJUSTMENT VALUE
Adjust the linear position of the sharp layer in VT
images (only with VT enabled).
2
Instrumentarium Dental
5140241-100 rev 3
Free Datasheet http://www.datasheet4u.net/







OC200 equivalent, schematic
2 Service program features
2.4 Sr 74 IOC: Display CPU input/output
signal check
For checking input and output signal states as seen by the
CPU. Check whether a signal reaches the CPU correctly,
when troubleshooting electrical problems related to e.g.
microswitches and buttons.
The I/O signals are divided into several pages, named 0L -
0H - 1L - 1H - 2L - 2H - 3L - 3H - 4L - 4H - 5L - 5H - 6L - 6H.
The tables below describe the signals shown on each
page.
The current page is shown on the kV/mA displays.
Individual signal states are shown as on/off signals by the
imaging program LEDs. A LED being lit means that the
corresponding signal is active. A hexadecimal number
summarizing the whole page is shown on the time/dose
display.
Usage:
1. Select Sr 74 IOC.
2. Use the left and right buttons to select page.
3. Check if the signal state shown on the control panel
matches the corresponding electrical signal level. If
not, the signal does not reach the CPU correctly.
4. Decide signal states according to the tables. For
trouble shooting electrical connections, use the CPU
board schematics to trace the signals.
NOTE! The control panel display is updated with a small
delay. Remember this when interpreting frequently
changing signals.
5. Press OK to exit the program.
10
Instrumentarium Dental
5140241-100 rev 3
Free Datasheet http://www.datasheet4u.net/










页数 42 页
下载[ OC200.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
OC200Orthoceph Service Program ManualInstrumentarium
Instrumentarium
OC200DOrthoceph Service Program ManualInstrumentarium
Instrumentarium

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight