DataSheet8.cn


PDF ( 数据手册 , 数据表 ) 6SE7023-4ECx1

零件编号 6SE7023-4ECx1
描述 Motion Control
制造商 Siemens
LOGO Siemens LOGO 


1 Page

No Preview Available !

6SE7023-4ECx1 数据手册, 描述, 功能
Motion Control
Selection and
ordering data
3/2
3/3
3/6
3/9
3/9
3/10
3/12
3/14
3/16
3/17
3/17
3/17
3/17
3/18
3/19
3/19
3/19
3/20
3/23
3/24
3/27
3/29
3/30
3/31
3/31
3/31
3/32
3/34
3/38
3/39
3/39
3/40
3/41
3/42
Converters and inverters
Á Order number examples
Á Basic units
Á Electronics options
Á Control board for compact and chassis units
Á Technology software
Rectifier units
AFE rectifier/regenerative units
Rectifier/regenerative units
Options
Á Supplementary Order codes
Á Isolation amplifier boards
Á SCI1 and SCI2 interface boards
Á Rectifier units and 24 V DC power supply unit
Á Coupling relay
DC link system components
Á Braking units and braking resistors
Á Capacitor module
Á DC link module
Á DC link bus bars
Line-side power options
Á Converters
Á Rectifier units
Á AFE rectifier/regenerative units
Á Rectifier/regenerative units,
25 % power-on duration
DC link power options
System components for braking units
and braking resistors
Interconnecting systems
Á Connection overview
Á Current carrying capacity of PVC-insulated
copper conductors
Á Correction factors
Á Power cables for 1FK., 1FT6, 1PH, 1PL6
Á Encoder cables
Mechanical system components
Operator control, visualization and
communication with SIMATIC
Á OP1S comfort operator control panel
Á APMU adapter for cabinet-door mounting
Á Communication package for SIMATIC S5
Á Start-up, parameterization and diagnostics
with DriveMonitor
Engineering system Drive ES
3
3/1Siemens DA 65.11 · 2003/20F0re4e Datasheet http://www.datasheet4u.com/







6SE7023-4ECx1 pdf, 数据表
SIMOVERT MASTERDRIVES Motion Control
Selection and ordering data
Converters and inverters
Compact
PLUS units
Compact and
chassis units
Electronics options · Additional boards and options
Designation
Order No.
Code1)
Weight,
approx.
kg
(lb)
Dimensions
WxHxD
mm x mm x mm
(in x in x in)
Accessories for compact and chassis units for expanding the electronic slots
ADB Adapter board
6SE7090–0XX84–0KA0
Adapter board, plugged into mounting position 2 (slots D and E)
Adapter board, plugged into mounting position 3 (slots F and G)
LBA Bus adapter for electronics box
6SE7090–0XX84–4HA0
Bus adapter for electronics box, integrated
K01
K02
K11
Accessories for SIMOLINK
SLP SIMOLINK pulse generator
6SX7005–0AD00
3 An incremental-encoder signal proportional to the speed is generated from a
setpoint in the SIMOLINK telegram; RS422, track A, B
SLE-DP SIMOLINK incremental encoder
6SX7005–0AG01
With PROFIBUS DP station at SIMOLINK, generates pulse series and zero
pulse from position setpoint telegram acc. to an RS422 incremental encoder
with either 1024, 2048, 4096 or 8192 S/R
SLS SIMOLINK switch
Changeover switch for SIMOLINK fiber-optic cables, 4 inputs/outputs
to 4 outputs/inputs, 12 different switching positions
6SX7005–0AE00
SLM
SIMOLINK monitor
Diagnostics box for monitoring the SIMOLINK telegrams, connection to a
measuring PC, evaluation of the data with diagnostic/analysis software
(PC software items are to be ordered separately)
6SX7005–0AF00
Extra package for SLB board
6SY7000–0AD15
5 m/16.4 ft plastic FOC cable, 2 FOC plug-in connectors, 1 plug-in connector for
the terminal strip, supplied with rough and fine glass paper (comes together
with the SLB board).
System package for SLB board
100 m/328 ft all-plastic FOC cable, 40 x FOC plug-in connectors,
20 x plug-in connectors for the terminal strip
6SX7010–0FJ50
Glass fiber-optic cable
(PCF = Polymer Cladding Fiber), up to a max. of 300 m/984.25 ft between two
SLB boards.
The following fiber-optic cable modules from Hewlett Packard are on the
SLB board
Transmitter: HFBR 1528
Receiver: HFBR 2528
on request
PROFIBUS plastic fiber optic, duplex-core
Plastic FOC with 2 cores,
PVC sheath, without connector for use in environments with low mechanical
stress
50 m (164 ft) ring
6XV1 821–2AN50
PROFIBUS plastic fiber optic, simplex connector/polishing set
6GK1 901–0FB00–0AA0
100 simplex connectors and 5 polishing sets for assembling PROFIBUS plastic
fiber-optic cables for the optical PROFIBUS DP
0.3 (0.7)
0.4 (0.9)
35 x 118 x 88
(1.4 x 4.6 x 3.5)
52 x 118 x 88
(2.0 x 4.6 x 3.5)
0.3 (0.7)
0.8 (1.8)
35 x 118 x 88
(1.4 x 4.6 x 3.5)
54 x 194 x 155
(2.1 x 7.6 x 6.1)
Additional options
OP1S Comfort operator control panel
OP1S cable (3 m/10 ft)
OP1S cable (5 m/16.4 ft)
PC cable (3 m/10 ft) for DriveMonitor and software/firmware
downloading
6SE7090–0XX84–2FK0
6SX7010–0AB03
6SX7010–0AB05
9AK1012–1AA00
1) When ordering the board, “–Z” and the corre-
sponding code for direct mounting in the
relevant slot must be appended to the inverters/
converters order no.
3/8 Siemens DA 65.11 · 2003/2004
Free Datasheet http://www.datasheet4u.com/







6SE7023-4ECx1 equivalent, schematic
SIMOVERT MASTERDRIVES Motion Control
Selection and ordering data
Options
Compact
PLUS units
Compact and
chassis units
Codes
Code Description
Size
MC+ = Motion Control Compact PLUS. n Standard. Ý Option available. – Not available.
Converter
Inverter
Rectifier unit
AFE
MC+ A–D E–G K
MC+ A–D E–G J
MC+ B–C E
Rectifier/rege-
nerative unit
CE
Line-side radio-interference suppression and protective devices
L03 Basic interference suppression
nnnÝ
n– – Ý
when radio-interference suppression
filters are used
L20 Operation of the converters with an Ý Ý Ý n n n n n
IT supply system
L30 Inverter fuses integrated, fuse type – – – – n n Ý n
for DIN/IEC approval and U
L33 Compact inverters without fuses – – – – – Ý n
–––
nnn
–––
–––
––
nn
––
––
3 Electrical options
K80 Safe Stop
Ý
ÝÝ
nÝ Ý Ý
–––
––
K91 DC link current measuring unit
––––
––––
ÝÝ
nn
Mechanical options
M20
Enclosure1) for increasing the degree n n Ý
of protection to IP20
nnÝ
nnÝ
nÝ
Documentation
D72 Documentation in Italian/English
ÝÝÝÝ
D77 Documentation in French/English Ý Ý Ý Ý
D78 Documentation in Spanish/English Ý Ý Ý Ý
D992) Supplied without documentation
ÝÝÝÝ
ÝÝÝÝ
ÝÝÝÝ
ÝÝÝÝ
ÝÝÝÝ
ÝÝÝ
ÝÝÝ
ÝÝÝ
ÝÝÝ
ÝÝ
ÝÝ
ÝÝ
ÝÝ
Brief description of the options
L03 Basic interference suppres-
sion when radio-inter-
ference suppression filters
are used with TT and TN sys-
tems
With the L03 option, unit sizes
J to X are fitted with discharge
capacitors in the DC link.
L20 Operation with an IT
system
See description in Section 4.
With the L20 option, operation
with non-earthed systems
(IT systems), the basic inter-
ference capacitors built in as
standard are removed.
L30 Integrated inverter fuses,
fuse type for DIN/IEC ap-
proval and
Option L30 can only be used
for inverter sizes E to G.
Inverter fuses are for protect-
ing inverters connected to a
DC bus. Inverter fuses must
always be provided when at
least 2 inverters are operated
on this bus. The inverters do
not have to be protected when
a single inverter of a rectifier
unit or a rectifier/regenerative
unit is supplied with matched
power. The same conditions
apply to a converter.
For option L30, the inverter
fuses indicated are integrated
in the inverter.
L33 Compact inverters without
fuses
For a description, see L30.
With the L33 option, which can
be used for compact inverters
sizes A to D, the inverter fuses
are not built into the inverter
and are not supplied with the
drive unit. The inverter fuses
must be ordered separately
and mounted externally (for
types, see page 3/23).
K80 Safe Stop
The function “Safe Stop”is a
“device for the prevention of
an unexpected start-up”to
EN 60 204-1, section 5.4. It is
realized in connection with an
external circuit.
The “Safe Stop”function can
be retrofitted by Siemens per-
sonnel only with converters
and inverters of frame sizes
E to K.
K91 DC link current measure-
ment
In the rectifier unit sizes B, C
and E, the DC link current is
measured indirectly via the
line-side current transformers.
M20 IP20 panels
With the M20 option, unit
sizes E to G are provided with
an IP20 enclosure (wall mount-
ing possible). Control is via a
PMU built into the front panel.
D72 Documentation in Italian/
English
Operating instructions are sup-
plied in Italian/English.
D77 Documentation in French/
English
Operating instructions are sup-
plied in French/English.
D78 Documentation in Spanish/
English
Operating instructions are sup-
plied in Spanish/English.
D992) Supplied without operating
instructions and without
DriveMonitor
If this option is chosen, no
operating instructions or tools
in the form of paper or soft-
ware (no CD-ROM) are en-
closed.
1) The enclosures can also be supplied separately.
See “Selection and ordering data – Mechanical
components”.
3/16
Siemens DA 65.11 · 2003/2004
2) In accordance with EU guidelines, the orderer of
this option must ensure that the documentation
is made available to the end user in the context
of the machine and equipment documentation.
Free Datasheet http://www.datasheet4u.com/










页数 30 页
下载[ 6SE7023-4ECx1.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
6SE7023-4ECx1Motion ControlSiemens
Siemens
6SE7023-4ECx1Motion ControlSiemens
Siemens
6SE7023-4ECx1Motion ControlSiemens
Siemens

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight


DataSheet8.cn    |   2020   |  联系我们   |   搜索  |  Simemap