SYSMAC CJ-series CJ2M CPU Units
CJ2M-CPU3@/-CPU1@www.DataSheet4U.com
CSM_CJ2M-CPU3__-CPU1_DS_E_1_2
Since 2001, CJ1M-series PLCs are in
control of a wide variety of
applications worldwide.
The accumulated experience and
advancements in technology now
result in CJ2M; fully compatible, yet
fully new.
• Increased performance, and increased memory capacity
• Up to 40 I/O units on any CPU
• USB for plug-and-play access to the PLC
• All models available with or without Ethernet port
• Choice of serial port plug-in modules
• User-friendly programming, faster debugging
CJ2M-CPU3@
CJ2M-CPU1@
Features
Five variations in program capacity from 5K steps to 60K steps; scale the CPU to your application needs.
Faster processors; LD instruction execution time is reduced to 40 ns, floating point trigonometrics in less than 1 μs.
Faster Function Block calls and execution, faster interrupt handling, less overhead time.
Added execution memory for Function Blocks allows structured, object-oriented programming even in entry-level CPUs.
General-purpose Ethernet port supports EtherNet/IP tag-based data links, connection to Support Software, communications between PLCs,
FTP data transfers, and more (CJ2M-CPU3@).
Standard USB port on all models allows Support Software to connect directly through standard USB cable.
A Serial Option Module can be mounted to add RS-232C or RS-422A/485 communications ports (CJ2M-CPU3@).
Compatible with all existing CJ1 power supply-, I/O-, control- and communication units.
1







CJ2M-CPU34 pdf, 数据表
CJ2M-CPU3@/-CPU1@
www.DataSheet4U.com
Function
Description
Communications
Peripheral (USB)
Port
Peripheral Bus
Bus for communications with various kinds of Support Software running on a personal
computer. High-speed communications are supported.
Serial Port (Option) *9
Application is possible when a Serial Communications Option Board is mounted.
Host Link (SYSWAY) Communications
Host Link commands or FINS commands placed between Host Link headers and terminators
can be sent from a host computer or PT to read/write I/O memory, read/control the operating
mode, and perform other operations for PLC.
No-protocol Communications
I/O instructions for communications ports (such as TXD/RXD instructions) can be used for
data transfer with peripheral devices such as bar code readers and printers.
NT Link Communications
I/O memory in the PLC can be allocated and directly linked to various PT functions, including
status control areas, status notification areas, touch switches, lamps, memory tables, and
other objects.
Peripheral Bus
Bus for communications with various kinds of Support Software running on a personal
computer. High-speed communications are supported.
Serial Gateway
This gateway enables receiving and automatically converting FINS to the CompoWay/F.
Serial PLC Links
Data is exchanged between CPU Units using serial ports without communications
programming. PTs set to the 1:N NT Link protocol can be included in the network.
EtherNet/IP Port *10
100Base-TX/10Base-T
Protocols: TCP/IP, UDP, ARP, ICMP (ping only), BOOTP
Applications: FINS, CIP, SNTP, DNS (Client), FTP (Server)
CIP Tag Data Links
Communications
Service
Message Communications
Programless cyclic data exchanges with the devices on the EtherNet/IP network.
Any CIP commands can be received from the devices on the EtherNet/IP network.
FINS
Communications Message Communications
Service
Any FINS commands can be transferred with the devices on the EtherNet/IP network.
Scheduled Interrupts
Tasks can be executed at a specified interval (minimum of 0.2 ms, Unit: 0.1 ms).
Resetting and restarting with MSKS(690)
When MSKS(690) is executed, the internal timer is restarted and the time to first interrupt is
set to a fixed value.
Interrupt
Reading present value of internal timer with
MSKS(690)
Power OFF Interrupts
MSKS(690) can be used to read the time that has elapsed until the schedule interrupt is started
or since the previous scheduled interrupt.
A task can be executed when CPU Unit's power turns OFF.
I/O Interrupt Tasks
A task can be executed when an input signal is input to an Interrupt Input Unit.
External Interrupt Tasks
A task can be executed when interrupts are requested from a Special I/O Unit or a CPU Bus
Unit.
Clock Function
Clock data is stored in memory.
Accuracy (Accuracy depends on the temperature.)
Ambient temperature of 55°C : 3.5 to +0.5 min error per month
Ambient temperature of 25°C : 1.5 to +1.5 min error per month
Ambient temperature of 0°C : 3 to +1 min error per month
Operation Start Time Storage
The time when operating mode was last changed to RUN mode or MONITOR mode is stored.
Clock
Operation Stop Time Storage
Startup Time Storage
The last time a fatal error occurred or the last time the operating mode was changed to
PROGRAM mode is stored.
The time when the power was turned ON is stored.
Power Interruption Time Storage
The time when the power is turned OFF is stored.
Total Power ON Time Calculation
The total time that the PLC has been ON is stored in increments of 10 hours.
Power ON Clock Data Storage
A history of the times when the power was turned ON is stored.
User Program Overwritten Time Storage
The time that the user program was last overwritten is stored.
Parameter Date Storage
The time when the Parameter Area was overwritten is stored.
Memory Protection
Power
Supply
Management Power OFF Detection Time Setting
Holding Area data, DM Area data, EM Area data, Counter Completion Flags, and counter
present values are held even when power is turned OFF. CIO Area, Work Area, some Auxiliary
Area data, and Timer Completion Flags, timer present values, index registers, and data
registers can be protected by turning ON the IOM Hold Bit in the Auxiliary Area, and by also
setting the IOM Hold Bit to “Hold” in the PLC Setup.
The detection time for power interruptions can be set.
AC power supply: 10 to 25 ms (variable)
DC power supply: 2 to 5 ms (CJ1W-PD022) or 2 to 20 ms (CJ1W-PD025)
Power OFF Detection Delay Time
The detection of power interruptions can be delayed: 0 to 10 ms
(Not supported by the CJ1W-PD022.)
Number of Power Interruptions Counter
The number of times power has been interrupted is counted.
*9.A Serial Option Board is required to use a serial port for the CJ2M-CPU3@ CJ2M CPU Unit.
*10.Supported only by the CJ2M-CPU3@.
8







CJ2M-CPU34 equivalent, schematic
Related Manuals
CJ2M-CPU3@/-CPU1@
www.DataSheet4U.com
Cat. No.
Model
W472
CJ2H-CPU6@-EIP
CJ2H-CPU6@
CJ2M-CPU@@
W473
CJ2H-CPU6@-EIP
CJ2H-CPU6@
CJ2M-CPU@@
W474
W342
W465
W463
W446
CJ2H-CPU6@-EIP
CJ2H-CPU6@
CJ2M-CPU3@
CJ2M-CPU1@
CS1G/H-CPU@@H
CS1G/H-CPU@@-V1
CJ1G/H-CPU@@H
CJ1G-CPU@@
CJ1M-CPU@@
NSJ@-@@@@(@)-@@@
CJ2H-CPU6@-EIP
CJ2H-CPU6@
CJ2M-CPU@@
CS1G/H-CPU@@H
CS1G/H-CPU@@-V1
CS1D-CPU@@H
CS1D-CPU@@S
CS1W-SCU@@-V1
CS1W-SCB@@-V1
CJ1H-CPU@@H-R
CJ1G/H-CPU@@H
CJ1G-CPU@@P
CJ1M-CPU@@
CJ1G-CPU@@
CJ1W-SCU@@-V1
CP1H-X@@@@-@
CP1H-XA@@@@-@
CP1H-Y@@@@-@
NSJ@-@@@@(@)-@@@
CJ2H-CPU6@-EIP
CJ2M-CPU3@
CS1W-EIP21
CJ1W-EIP21
CXONE-AL@@C-V@/
AL@@D-V@
W447
WS02-CXPC@-V@
W469
W366
WS02-SIMC1-E
W464
CXONE-AL@@C-V@/
CXONE-AL@@D-V@
Manual
CJ-series CJ2 CPU Unit
Hardware User’s
Manual
CJ-series CJ2 CPU Unit
Software User’s Manual
Application
Hardware specifications for CJ2
CPU Units
Software specifications for CJ2
CPU Units
Description
Describes the following for CJ2 CPU Units:
Overview and features
Basic system configuration
Part nomenclature and functions
Mounting and setting procedure
Remedies for errors
Also refer to the Software User’s Manual (W473).
Describes the following for CJ2 CPU Units:
CPU Unit operation
Internal memory
Programming
Settings
Functions built into the CPU Unit
Also refer to the Hardware User’s Manual (W472)
CS/CJ/NSJ-series
Instructions Reference
Manual
Information on instructions
Describes each programming instruction in detail.
Also refer to the Software User’s Manual (W473) when you
do programming.
CS/CJ/CP/NSJ-series
Communications
Command Reference
Manual
Information on communications
for CS/CJ/CP-series CPU Units
and NSJ-series Controllers
Describes C-mode commands and FINS commands
Refer to this manual for a detailed description of commands
for communications with the CPU Unit using C mode
commands or FINS commands.
Note: This manual describes the communications
commands that are addressed to CPU Units. The
communications path that is used is not relevant and
can include any of the following: serial ports on CPU
Units, communications ports on Serial
Communications Units/Boards, and Communications
Units. For communications commands addressed to
Special I/O Units or CPU Bus Units, refer to the
operation manual for the related Unit.
CS and CJ Series
EtherNet/IP Units
CS1W-EIP21, CJ1W-
EIP21, CJ2H-CPU6@-
EIP, CJ2M-CPU3@
Operation Manual
CX-One Setup Manual
CX-Programmer
Operation Manual
CX-Programmer
Operation Manual
Functions Blocks/
Structured Text
CX-Programmer
Operation Manual SFC
Programming
CS/CJ/CP/NSJ-series
CX-Simulator Operation
Manual
CS/CJ/CP/NSJ-series
CX-Integrator Network
Configuration Software
Operation Manual
Information for EtherNet/IP
function of CJ2M built-in
Ethernet port
Installing software from the CX-
One
Support Software for Windows
computers
CX-Programmer operating
procedure
Operating procedures for CX-
Simulator Simulation Support
Software for Windows
computers
Using simulation in the CX-
Programmer with CX-
Programmer version 6.1 or
higher
Network setup and monitoring
Describes EtherNet/IP port/units. A basic setting, a tag data
link, FINS communication, and other function are described.
Provides an overview of the CX-One FA Integrated Tool
Package and describes the installation procedure.
Describes operating procedures for the CX-Programmer.
Also refer to the Software User’s Manual (W473) and
Instructions Reference Manual (W474) when you do
programming.
Describes the operating procedures for the CX-Simulator.
When you do simulation, also refer to the CX-Programmer
Operation Manual (W446), Software User’s Manual (W473),
and CS/CJ/NSJ series Instructions Reference Manual
(W474).
Describes the operating procedures for the CX-Integrator.
16










页数 17 页
下载[ CJ2M-CPU34.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
CJ2M-CPU31SYSMAC CJ-series CJ2M CPU UnitsOmron
Omron
CJ2M-CPU32SYSMAC CJ-series CJ2M CPU UnitsOmron
Omron
CJ2M-CPU33SYSMAC CJ-series CJ2M CPU UnitsOmron
Omron
CJ2M-CPU34SYSMAC CJ-series CJ2M CPU UnitsOmron
Omron

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight


DataSheet8.cn    |   2020   |  联系我们   |   搜索  |  Simemap