DataSheet8.cn


PDF ( 数据手册 , 数据表 ) CJ1W-CLK

零件编号 CJ1W-CLK
描述 SYSMAC CJ-series Controller Link Units
制造商 Omron
LOGO Omron LOGO 


1 Page

No Preview Available !

CJ1W-CLK 数据手册, 描述, 功能
SYSMAC CJ-series Controller Link Units
CJ1W-CLK
www.DataSheet4U.com
CSM_CJ1W-CLK_DS_E_2_1
New Controller Link Units, Now with
4,000 Send Words
• The Controller Link is an FA network that can send and
receive large amounts of data easily and at high speed.
The Controller Link supports data links that enable sharing
data between PLCs and computers and a message
service that enables sending and receiving data whenever
required.
• Systems can be flexibly built by using Repeater Units to
enable T-branches, long-distance wiring, and converting
part of the network to optical cable.
Features
CJ1W-CLK23
Large-capacity data links are easily achieved without programming simply by setting data link tables.
Up to 20,000(See note 1.) send/receive words can be set per node for Units (up to 62,000 words for Boards).
Data links can be performed with up to 4,000(See note 2.) words per node while ensuring data concurrency.
User-set data link tables can be changed while data links are operating.(See note 3.)
Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.
Note: 1. Supported for unit version 1.2 or later.
2. CJ1W-CLK23 and 3G8F7-CLK@3 are supported.
3. Supported for CJ1W-CLK23, 3G8F7-CLK@3, and models ending with "-V1".
System Configuration
Wired Controller Link Units
Basic Wiring (Daisy Chain Connection)
AAAA
B
(1)
Long-distance Wiring
A
(1)
D
1km Max. *
(1)
D
A
B
1km Max. *
1km Max. *
1km Max. *
A: Wired Controller Link Unit
B: Wired Controller Link Support Board
C: Wire-to-Optical Repeater Unit
D: Wire-to-Wire Repeater Unit
* At 500 kbits/s
(1): Twisted-pair cable
(2): Optical cable
T-Branch Wiring, Partial Conversion to
B Optical Cable
AA
A
(1)
(1) C
(2)
D
A
C (1)
B
(1)
B
A
A
1







CJ1W-CLK pdf, 数据表
Differences in Specifications of New and Old Models
CJ1W-CLK
www.DataSheet4U.com
Controller Link Units
Functions
CJ1W-CLK23
CJ1W-CLK21-V1
Note: The following
Note: The following models
models are discontinued.
are discontinued.
CJ1W-CLK21-V1
CJ1W-CLK21
Unit version 2.0
Unit version 1.2
Pre-Ver. 1.2
Pre-Ver. 1.2
Number of data link send
words (data link areas that are
created for a single node in a
single PLC)
20,000 max.
12,000 max.
Number of send words per
node (total of area 1 and area
2)
4,000 words max.
(user-set links only)
1,000 words max.
Data Link Area
Allocation setting can be performed for same areas in Allocation setting can be performed for same areas in
areas 1 and 2.
areas 1 and 2.
Max. Units mountable per PLC 8 Units
4 Units
Automatic data link setting
Choose from equality layout or 1:N allocations (common type, 1:1, chain type)
Supported for equality
layout only.
Changing data link allocations
during active data links
Supported (Data link tables can be changed during active data links.)
Not supported.
Maximum connectable nodes 62 nodes (See note 1.)
32 nodes
Mixed use
Yes (See note 2.)
Compatible support software
CX-Integrator for CX-One
V2.1or higher, or CX-Net
for CX-Programmer Ver.
7.2 or higher
CX-Net for
CX-Programmer Ver. 5.0
or higher
CX-Net for
CX-Programmer Ver. 3.2
or higher
CX-Net for
CX-Programmer Ver. 1.0
or higher
Note: 1. For wired models, the maximum number of nodes is 32 if Repeater Units are not used.
2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications
for the old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed.
Controller Link Support Boards (for PCI Bus)
Functions
3G8F7-CLK23-E
3G8F7-CLK21-EV1
Note: The following models are
discontinued.
3G8F7-CLK21-E
Number of data link send/
receive words (data link areas
for sending/receiving that are
created for a single node in a
single computer)
62,000 max.
32,000 max.
Send words per node
4,000 words max.
(user-set links only)
1,000 words max.
Changing data link allocations
during active data links
Supported. (Data link tables can be changed during active data links.)
Not supported.
Maximum connectable nodes 62 nodes (See note 1.)
32 nodes
Mixed use
Yes (See note 2.)
Compatible FinsGateway and
version of supplied CD
(See note 3.)
FinsGateway Version 2003.21 or
higher (CD Ver. 3.00 or higher)
FinsGateway Version 2003.00 or
higher (CD Ver. 2.00 or higher)
FinsGateway Version 3.00 or
higher (CD Ver. 1.00 or higher)
Compatible support software
CX-Integrator for CX-One Ver. 2.1
or higher , or CX-Net for
CX-Programmer Ver. 7.2 or higher
CX-Net for CX-Programmer Ver.
3.2 or higher
CX-Net for Ver. 1.0 or higher
Note: 1. For wired models, the maximum number of nodes is 32 if repeater units are not used.
2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications
for the old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed..
3. FinsGateway Version 2003 is compatible with Windows XP and Windows 2000. For Windows NT4.0 (Service Pack 3 or higher), Windows
ME, or Windows 98SE, use FinsGateway Version3. (With FinsGateway Version 3, only functions supported by the 3G8F7-CLK21 can
be used.)
8














页数 11 页
下载[ CJ1W-CLK.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
CJ1W-CLKSYSMAC CJ-series Controller Link UnitsOmron
Omron

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight


DataSheet8.cn    |   2020   |  联系我们   |   搜索  |  Simemap