www.DataSheet4U.com
Relays
Sockets
RU/RR/RH/RM/RY & Latch Relays
General-purpose electromechanical relays
Relay sockets for mounting in three ways
(04/10/25)
RU Series Universal Relays
Fuwlwlwf.DeaatatSuhreeet4dU.uconmiversal miniature relays
Designed with environment taken into consideration
• Two terminal styles: plug-in and PCB mount
• Non-polarized LED indicator available on plug-in relays
• No internal wires, lead-free construction
• Cadmium-free contacts
• Mechanical flag indicator available on plug-in relays
• Manual latching lever with color coding for AC or DC coil
• Snap-on yellow marking plate; optional marking plates are
available in four other colors
• Maximum contact ratings: 10A (RU2), 6A (RU4), 3A (RU42)
• UL, CSA, c-UL, EN compliant
Standard
UL508
CSA C22.2 No. 14
CSA C22.2 No. 14
Mark
Approval Organization / File No.
UL/c-UL File No. E66043
CSA File No. LR35144
(CSA mark is printed on bifurcated
contact types only)
EN61810-1
TÜV Product Service
Self declaration
(EC Low Voltage Directive)
With Latching Lever
Mechanical Indicator
The contact position can be confirmed
through the file small windows.
Lever in the Latched Position
Marking Plate
Standard yellow marking plate is easily
replaced with optional marking plates in four
colors for easy identification of relays.
Latching Lever
Using the latching lever, operation can be
checked without energizing the coil. The latching
lever is color coded for AC and DC coils.
AC coil: Orange
DC coil: Green
In Normal Operation
LED Indicator
Non-polarized green LED indicator is
standard provision for plug-in terminal,
latching lever types
Without Latching Lever
Mechanical Indicator
Marking Plate
Note: Turn off the power to the relay coil when using
the latching lever. After checking the operation,
return the latching lever in the normal position.
AC/DC Color Marking
For identification of AC or DC coils.
AC coil: Yellow
DC coil: Blue
LED Indicator
Non-polarized green LED indicator is
standard provision for plug-in terminal
types, except for simple types.
AC Coil
DC Coil
8 (04/10/25)
RR Series Power Relays
Cownwtwa.DcattaRShaeetit4nUg.csom
Maximum Contact Capacity
Allowable Contact Power
Continuous
Current Resistive
Load
Inductive
Load
Voltage
Rated Load
Resistive Inductive
Load
Load
110V AC
10A
10A
1650VA AC 1100VA AC
300W DC 150W DC
220V AC
7.5A
30V DC
10A
7.5A
5A
5A
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
• UL Ratings
Voltage
240V AC
120V AC
Resistive
10A
10A
General use
7A
7.5A
Horse Power
Raging
1/3 HP
1/4 HP
30V DC
10A 7A
—
• CSA Ratings
Voltage
240V AC
120V AC
100V DC
30V DC
Resistive
10A
10A
—
10A
• TÜV Ratings
240V AC
30V DC
AC: cos ø = 1.0, DC: L/R = 0 ms
10A
10A
Specifications
Contact Material
Contact Resistance
Minimum Applicable Load
Operate Time
Release Time
Power Consumption
(approx.)
Insulation Resistance
Dielectric Strength
∗1
∗2
∗2
Pin Terminal
Blade Terminal
Operating Frequency
Vibration Resistance
Shock Resistance
Electrical Life
Mechanical Life
Operating Temperature
Operating Humidity
Weight (approx.) (Basic type)
∗3
Silver
30 mΩ maximum
24V DC, 10 mA; 5V DC, 20 mA (reference value)
25 ms maximum
25 ms maximum
AC: 3 VA (50 Hz), 2.5 VA (60 Hz)
DC: 1.5W
100 MΩ minimum (500V DC megger)
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
1500V AC, 1 minute
1500V AC, 1 minute
1500V AC, 1 minute
1000V AC, 1 minute
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
2000V AC, 1 minute
2000V AC, 1 minute
2000V AC, 1 minute
1000V AC, 1 minute
Electrical:
Mechanical:
1800 operations/h maximum
18,000 operations/h maximum
Damage limits:
Operating extremes:
Damage limits:
Operating extremes:
10 to 55 Hz, amplitude 0.5 mm
10 to 55 Hz, amplitude 0.5 mm
1000 m/s2
100 m/s2
200,000 operations (220V AC, 5A)
10,000,000 operations
–25 to +40°C (no freezing)
5 to 85% RH (no condensation)
RR2P: 90g, RR3P/RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g
Note: Above values are initial values.
∗1: Measured using 5V DC, 1A voltage drop method
∗2: Measured at the rated voltage (at 20°C), excluding contact bouncing
∗3: For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve.
General use
7A
7.5A
0.5A
7.5A
16 (04/10/25)
|
|||
页数 | 30 页 | ||
下载 | [ RR3P-U.PDF 数据手册 ] |
零件编号 | 描述 | 制造商 |
RR3P-U | Power Relay | IDEC |
零件编号 | 描述 | 制造商 |
STK15C88 | 256-Kbit (32 K x 8) PowerStore nvSRAM | Cypress Semiconductor |
NJM4556 | DUAL HIGH CURRENT OPERATIONAL AMPLIFIER | New Japan Radio |
EL1118-G | 5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLER | Everlight |
DataSheet8.cn | 2020 | 联系我们 | 搜索 | Simemap |