SELF-DIAGNOSTIC FUNCTION
KV-32HS500/32HV600/34DRC500/34XBR800/ 36HS500/
36XBR800/38DRC500/40XBR800/42DRC800
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to ßash. The number
of times the LED ßashes translates to a probable source of the problem. A deÞnition of the STANDBY/TIMER LED ßash indicators is listed in the
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will ßash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the LED will identify the Þrst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
www.DataSheet4U.Dcioamgnostic Item
Power does not turn on
+B Overcurrent (OCP)*
Low +B Overvoltage (OVP)
Vertical Deflection Stopped
White Balance Failure
(not balanced)
LOW +B OCP/OVP
(overcurrent/overvoltage)***
Horizontal Deflection
Stopped
No. of times
STANDBY /
TIMER lamp
flashes
Does not light
2 times
3 times
4 times
5 times
6 times
7 times
Display
Result
Probable Cause Location
Detected Symptoms
_______
2:0 or 2:1
3:0 or 3:1
4:0 or 4:1
5:0 or 5:1
6:0 or 6:1
7:0 or 7:1
Power cord is not plugged in.
Fuse is burned out (F501). (A Board)
H.OUT (Q5030) is shorted. (D Board)
+B PWM (Q5003) is shorted.
(D Board)
IC6505 is faulty. (D Board)
15V is not supplied. (D Board)
IC5004 is faulty. (D Board)
Video OUT (IC9001-IC9003) is faulty.
(CH, CX Board)
CRT drive (IC2801) is faulty. (B Board)
G2 is improperly adjusted.**
+5 line is overloaded. (A, B, M Boards)
+5 line is shorted. (A, B, M Boards)
IC504 is faulty. (A Board)
Power does not come on.
No power is supplied to the TV.
AC Power supply is faulty.
Power does not come on.
Load on power line shorted.
Has entered standby mode.
Has entered standby mode after
Horizontal raster.
Vertical deflection pulse is stopped.
Power line is shorted or power
supply is stopped.
No raster is generated.
CRT cathode current detection
reference pulse output is small.
No picture
No picture
* If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the
microcontroller is displayed on the screen.
** Refer to Screen (G2) in Section 2-5 of this manual.
*** If STANDBY/STEREO LED flashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment.
Display of Standby/Timer LED Flash Count
Diagnostic items
+B Overcurrent
Flash count
2 times
Low +B Overvoltage
Vert. Deflection Stopped
3 times
4 times
White Balance Failure
Low +B OCP/OVP
5 times
6 times
Horiz. Deflection Stopped 7 times
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
Lamp OFF 3 sec.
Standby/Timer LED
* One ßash count is not used for
self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from ßashing.
—9—







KV-32HS500 equivalent, schematic
KV-32HS500/32HV600/34DRC500/34XBR800/ 36HS500/
36XBR800/38DRC500/40XBR800/42DRC800
11. LLMB (Left Lower Middle BOW)
2-4.1. DYNAMIC FOCUS/DYNAMIC QUADRA-
POLE DATA
Normally, no adjustments are necessary for these systems. If for some
reason the data is lost, use the following data:
BR
12. CADJ Fix 29
2-4. FOCUS ADJUSTMENT
Confirm neck assembly Z axis position. (See Figure 1)
1. Input a dot signal.
www.Data2S.heSeett4VUi.dceoomMode to STANDARD.
3. Adjust focus VR clockwise (DE-Focus) to confirm that the dot’s shape
is centered. (Figure 2 & 3) Confirm neck assembly rotation by W Board
position. W Board should be level ±1º. Adjust as necessary to balance
dot shape along center horizontal line, then refocus.
4. Input a HD monoscope signal.
5. Confirm center focus with focus VR.
Write the data from any non-vertically compressed mode, then use the
CPY1 function (CXA2170D-4 Item 6) to copy the data to the vertical
compressed modes. V-compressed data is identical to non-v-compressed
data. Service personnel with a trained eye can adjust the
DF or DQP registers to adjust DF phase (Item 7) or DQP
phase (Item 8), respectively, to balance left and right focus.
Refrain from adjusting more than 5 steps from table data below.
Further adjustment indicates a circuit problem -- troubleshoot to
cause. Be sure that Neck Assembly is in the proper location
(See Section 2-4 Figure 1) before changing DF/DQP data or
troubleshooting circuit when DF/DQP is suspect.
Figure 1
FOCUS
Screen (G2)
Figure 2
DOT SHAPE:
Figure 3
NOTE: Changing neck assembly position will affect corner convergence.
— 17 —










页数 30 页
下载[ KV-32HS500.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
KV-32HS500Color TVSony
Sony

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight


DataSheet8.cn    |   2020   |  联系我们   |   搜索  |  Simemap