零件编号 | LA55-P | ||
描述 | Current Transducer LA 55-P | ||
制造商 | LEM | ||
LOGO | |||
1 Page
www.DataSheet4U.com
Current Transducer LA 55-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 50 A
Electrical data
IPN Primary nominal r.m.s. current
I Primary current, measuring range
P
RM Measuring resistance @
50
0 .. ± 70
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
A
A
with ± 12 V
with ± 15 V
@ ± 50 A
max
@ ± 70 A max
@ ± 50 A
max
@ ± 70 A max
10 100 60 95 Ω
10 50 601) 601) Ω
50 160 135 155 Ω
50 90 13 52) 1352) Ω
ISN Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC Current consumption
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50 mA
1 : 1000
± 12 .. 15
V
10 (@ ±15 V) + IS mA
2.5 kV
Accuracy - Dynamic performance data
X Accuracy @ I , T = 25°C
PN A
@ ± 15 V (± 5 %) ± 0.65
@ ± 12 .. 15 V (± 5 %) ± 0.90
ε Linearity
L
< 0.15
%
%
%
Typ Max
I Offset current @ I = 0, T = 25°C
O PA
± 0.2 mA
IOM Residual current 3) @ IP = 0, after an overload of 3 x IPN
± 0.3 mA
I Thermal drift of I
OT O
0°C .. + 70°C ± 0.1 ± 0.5 mA
- 25°C .. + 85°C ± 0.1 ± 0.6 mA
tra
t
r
di/dt
f
Reaction time @ 10 % of IP max
Response time @ 90 % of I
P max
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 500
<1
> 200
DC .. 200
ns
µs
A/µ s
kHz
General data
TA Ambient operating temperature
TS Ambient storage temperature
R S Secondary coil resistance @
m Mass
Standards 4)
TA = 70°C
TA = 85°C
- 25 .. + 85
- 40 .. + 90
80
85
18
EN 50178
°C
°C
Ω
Ω
g
Features
•Closed loop (compensated) current
transducer using the Hall effect
•Printed circuit board mounting
•Insulated plastic case recognized
according to UL 94-V0.
Advantages
•Excellent accuracy
•Very good linearity
•Low temperature drift
•Optimized response time
•Wide frequency bandwidth
•No insertion losses
•High immunity to external
interference
•Current overload capability.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
(UPS)
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
applications.
Notes : 1) Measuring range limited to ± 60 A
max
2) Measuring range limited to ± 55 A
max
www.D34)) RAaetlisasutSltoofhfcetohreeretcs4opUeornc.dicvineogfmiteeldstsofisthaevmaialagbnleetic circuit
980706/8
LEM Components
w w w .lem.com
|
|||
页数 | 2 页 | ||
下载 | [ LA55-P.PDF 数据手册 ] |
零件编号 | 描述 | 制造商 |
LA55-P | Current Transducer LA 55-P | LEM |
LA55-TP | Current Transducer LA 55-TP | LEM |
零件编号 | 描述 | 制造商 |
STK15C88 | 256-Kbit (32 K x 8) PowerStore nvSRAM | Cypress Semiconductor |
NJM4556 | DUAL HIGH CURRENT OPERATIONAL AMPLIFIER | New Japan Radio |
EL1118-G | 5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLER | Everlight |
DataSheet8.cn | 2020 | 联系我们 | 搜索 | Simemap |