6. Absolute Maximum Ratings :
PD104VT2
The followings are maximum values , which if exceeded, may cause faulty operation or
damage to the unit.
GND=0V, Ta=25
Parameters
Supply Voltage
Input Signal Voltage
Backlight Driving Voltage
Backlight Driving Frequency
Storage Temperature
Operating Temperature
Symbol
Vcc
VIN
VL
FL
TST
TOP
MIN.
-0.3
-0.3
-
0
-10
-10
MAX.
+4.0
Vcc+0.3
2000
100
+70
+60
Unit
V
V
V
KHz
Remark
Note 6-1
Note 6-2
Note 6-1 : Input signals include CLK , Hsync , Vsync , DENB , R[0:5] , G[0:5] and B[0:5].
Note 6-2 : Optical characteristics shown in Table 9-1 are measured under Ta=+25 .
7.Electrical Characteristics
7-1) Recommended Operating Conditions:
GND = 0V Ta = 25
Item
Symbol Min. Typ. Max. Unit
Remark
Supply Voltage
Current Dissipation
Digital input voltage
Lamp Current
Lamp Voltage
Lamp Initial Voltage
H level
L level
Vcc 3.0 3.3 3.6 V
Icc - 300 390 mA
VIN 0.7 VCC -
VCC
V
VIL -0.1
- 0.1 VCC V
IFL
3.0 6.0 8.0 mA
VL 540 540 650 Vrms
VSFL
-
- 1060 Vrms
Note 7-1
Per CCFL
Note 7-2
Note 7-4
Note 7-2
at Ta=25 C
Note 7-3
Lamp Driving Frequency
Lamp Life Time
--
FL 50 60
30000 -
1300
70
KHz
Hrs
at Ta=0 C
Note 7-3
Note 7-5
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd. Page:8
Note 9-1 The definitions of viewing angles are as follow
PD104VT2
12 o’clock
Lamp connector
3 o’clock
9 o’clock
6 o’clock
Note 9-2 : The definition of contrast ratio
Note 9-3 Topcon BM-5A luminance meter 1 field of view is used in the testing (after 30 minutes’
operation). The typical luminance value is measured at lamp current 12.0 mA.
Note 9-4: Definition of Response Time Tr and Tf:
100%
90%
White
Black
White
10%
0%
Tr
Tf
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co.,
Ltd. Page:16
|
|||
页数 | 23 页 | ||
下载 | [ PD104VT2.PDF 数据手册 ] |
零件编号 | 描述 | 制造商 |
PD104VT1 | LCD_Module | PRIME_VIEW |
PD104VT2 | LCD Module | PRIME_VIEW |
PD104VT3 | LCD_Module | PRIME_VIEW |
PD104VT5 | Display Module | Prime View |
零件编号 | 描述 | 制造商 |
STK15C88 | 256-Kbit (32 K x 8) PowerStore nvSRAM | Cypress Semiconductor |
NJM4556 | DUAL HIGH CURRENT OPERATIONAL AMPLIFIER | New Japan Radio |
EL1118-G | 5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLER | Everlight |
DataSheet8.cn | 2020 | 联系我们 | 搜索 | Simemap |