ADE7752/ADE7752A
FEATURES
High accuracy, supports 50 Hz/60 Hz IEC62053-2x
Less than 0.1% error over a dynamic range of 500 to 1
Compatible with 3-phase/3-wire delta and 3-phase/4-wire
Wye configurations
The ADE7752 supplies average real power on frequency
outputs F1 and F2
High frequency output CF is intended for calibration and
supplies instantaneous real power
Logic output REVP indicates a potential miswiring or
negative power for each phase
Direct drive for electromechanical counters and 2-phase
stepper motors (F1 and F2)
Proprietary ADCs and DSP provide high accuracy over large
variations in environmental conditions and time
On-chip power supply monitoring
On-chip creep protection (no load threshold)
On-chip reference 2.4 V ±8% (20 ppm/°C typical) with
external overdrive capability
Single 5 V supply, low power
60 mW typical: ADE7752
30 mW typical: ADE7752A
Low cost CMOS process
GENERAL DESCRIPTION
The ADE7752 is a high accuracy polyphase electrical energy
measurement IC. The ADE7752A is a pin-to-pin compatible
low power version of ADE7752. The functions of ADE7752 and
ADE7752A are the same. Both products are referred to in the
text of this data sheet as ADE7752.
The part specifications surpass the accuracy requirements as
quoted in the IEC62053-2x standard. The only analog circuitry
used in the ADE7752 is in the analog-to-digital converters (ADCs)
and reference circuit. All other signal processing (such as multi-
plication, filtering, and summation) is carried out in the digital
domain. This approach provides superior stability and accuracy
over extremes in environmental conditions and over time.
The ADE7752 supplies average real power information on the
low frequency outputs, F1 and F2. These logic outputs may be
used to directly drive an electromechanical counter or to
interface with an MCU. The CF logic output gives instanta-
neous real power information. This output is intended to be
used for calibration purposes.
The ADE7752 includes a power supply monitoring circuit on
the VDD pin. The ADE7752 remains inactive until the supply
voltage on VDD reaches 4 V. If the supply falls below 4 V, no
pulses are issued on F1, F2, and CF. Internal phase matching
circuitry ensures that the voltage and current channels are
phase matched. An internal no load threshold ensures the part
does not exhibit any creep when there is no load. The ADE7752
is available in a 24-lead SOIC package.
FUNCTIONAL BLOCK DIAGRAM
IAP 5
IAN 6
VAP 16
IBP 7
IBN 8
VBP 15
ICP 9
ICN 10
VCP 14
VN 13
ADC
ADC
ADC
ADC
ADC
ADC
2.4V REF
11
AGND
4kΩ
12
REFIN/OUT
HPF
Φ
PHASE
CORRECTION
HPF
Φ
PHASE
CORRECTION
HPF
Φ
PHASE
CORRECTION
ABS
17
VDD
3
X
LPF
POWER
SUPPLY
MONITOR
ADE7752/
ADE7752A
XΣ
LPF
2 DGND
19 CLKIN
20 CLKOUT
X
LPF
DIGITAL-TO-FREQUENCY CONVERTER
4 18 21 22 23 24 1
REVP SCF S0 S1 F2 F1 CF
Figure 1. 24-Lead Standard Small Outline Package [SOIC]
Rev. C
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice.
No license is granted by implication or otherwise under any patent or patent rights of Analog
Devices.Trademarksandregisteredtrademarksarethepropertyoftheirrespectiveowners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
© 2005 Analog Devices, Inc. All rights reserved.







ADE7752A pdf, 数据表
ADE7752/ADE7752A
TYPICAL PERFORMANCE CHARACTERISTICS
0.5
WYE CONNECTION
0.4 ON-CHIP REFERENCE
0.3
PHASE C
0.2
PHASE A
0.1
0 PHASE B
PHASE A + B + C
–0.1
–0.2
–0.3
–0.4
–0.5
0.1
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 4. Error as a Percent of Reading
with Internal Reference (Wye Connection)
1.0
WYE CONNECTION
0.8 ON-CHIP REFERENCE
0.6 +85°C PF = +0.5
0.4 +25°C PF = –0.5
0.2
0
–0.2 +25°C PF = +1
–0.4 –40°C PF = +0.5
–0.6
–0.8
–1.0
0.1
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 5. Error as a Percent of Reading over Power Factor
with Internal Reference (Wye Connection)
0.5
WYE CONNECTION
0.4 EXTERNAL REFERENCE
0.3 +85°C PF = +0.5
0.2
0.1 +25°C PF = +1
0
–0.1
–40°C PF = +0.5
–0.2
+25°C PF = –0.5
–0.3
–0.4
–0.5
0.1
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 6. Error as a Percent of Reading over Power Factor
with External Reference (Wye Connection)
1.0
WYE CONNECTION
0.8 ON-CHIP REFERENCE
+85°C PF = 1
0.6
0.4
0.2
0
–0.2 +25°C PF = 1
–40°C PF = 1
–0.4
–0.6
–0.8
–1.0
0.1
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 7. Error as a Percent of Reading over Temperature
with Internal Reference (Wye Connection)
0.5
0.4
0.3
0.2
0.1
0
–0.1
–0.2
–0.3
–0.4
–0.5
0.1
DELTA CONNECTION
ON-CHIP REFERENCE
PF = –0.5
PF = +1
PF = +0.5
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 8. Error as a Percent of Reading over Power Factor
with Internal Reference (Delta Connection)
0.5
WYE CONNECTION
0.4 EXTERNAL REFERENCE
0.3
0.2 +85°C PF = 1
0.1
0
+25°C PF = 1
–0.1
–0.2 –40°C PF = 1
–0.3
–0.4
–0.5
0.1
1 10
CURRENT CHANNEL (% of Full Scale)
100
Figure 9. Error as a Percent of Reading over Temperature
with External Reference (Wye Connection)
Rev. C | Page 8 of 24







ADE7752A equivalent, schematic
ADE7752/ADE7752A
Figure 21 shows the connections of the analog inputs of the
ADE7752 with the power lines in a 3-phase 3-wire delta service.
Note that only two current inputs and two voltage inputs of the
ADE7752 are used in this case. The real power calculated by the
ADE7752 does not depend on the selected channels.
Ra* Cf
Rb*
VR*
PHASE A
Rb*
CT
ANTIALIASING
FILTERS
VAP
IAP
IAN
SOURCE
PHASE B
PHASE C
CT
VN
Rf Cf
LOAD
Ra* Cf
Rb*
VR*
ANTIALIASING
FILTERS
Rb* IBP
IBN
VBP
* Ra >> Rf + VR * Rb + VR = Rf
Figure 21. 3-Phase 3-Wire Meter Connection with ADE7752
Figure 22 shows the connections of the analog inputs of the
ADE7752 with the power lines in a 3-phase 4-wire Wye service.
Ra* Cf
Rb*
VR*
Rb*
CT
ANTIALIASING
FILTERS
VAP
IAP
IAN
PHASE A
SOURCE
PHASE B
PHASE C
Ra* Cf
Rb*
VR*
CT
CT
ANTIALIASING
FILTERS
Rb*
IBP
IBN
VBP
Ra* Cf
Rb*
VR*
Rf
VN
ANTIALIASING
FILTERS
Rb* ICP LOAD
ICN
VCP
CF * Ra >> Rf + VR; * Rb + VR = Rf
Figure 22. 3-Phase 4-Wire Meter Connection with ADE7752
Rev. C | Page 16 of 24










页数 24 页
下载[ ADE7752A.PDF 数据手册 ]


分享链接

Link :

推荐数据表

零件编号描述制造商
ADE7752Polyphase Energy Metering ICAnalog Devices
Analog Devices
ADE7752APolyphase Energy Metering ICAnalog Devices
Analog Devices
ADE7752BPolyphase Energy Metering ICAnalog Devices
Analog Devices

零件编号描述制造商
STK15C88256-Kbit (32 K x 8) PowerStore nvSRAMCypress Semiconductor
Cypress Semiconductor
NJM4556DUAL HIGH CURRENT OPERATIONAL AMPLIFIERNew Japan Radio
New Japan Radio
EL1118-G5 PIN LONG CREEPAGE SOP PHOTOTRANSISTOR PHOTOCOUPLEREverlight
Everlight


DataSheet8.cn    |   2020   |  联系我们   |   搜索  |  Simemap